This work describes the effect of a Tee and a Valve on the flow measurement accuracy and the performances of the Etoile flow straightener described by the standard ISO 5167 to produce the fully developed pipe flow with these disturbances. Simulation is carried out for an air flow in 100mm pipe diameter with a Reynolds number between 10~4 and 10~6. The code used for this work is Fluent V6.3, where the Navier-Stokes equations are solved by the finite volumes method with K-e model like turbulent model. The results show that for the disturbance valve 50% closed, the length of establishment seems to be reached at 25D downstream the Etoile where the flow gyration angle is reduced practically to zero value. But for the Tee disturbance the results show that the flow needs more than 25D to reach the profiles requested by the standards. An experimental study is essential to validate these results for choosing a standard disturbance which will be examined with conditioners quoted in standard 5167 and thereafter the development of a new flow conditioner.
机译:这项工作描述了三通和阀门对流量测量精度的影响以及标准ISO 5167所描述的Etoile矫直机的性能,以产生具有这些干扰的充分发展的管道流量。对管道直径为100mm的气流进行了模拟,雷诺数在10〜4和10〜6之间。用于这项工作的代码是Fluent V6.3,其中Navier-Stokes方程是通过K-e模型(如湍流模型)通过有限体积法求解的。结果表明,对于50%关闭的扰动阀,似乎在Etoile下游25D处达到建立的长度,在该位置旋流角实际上减小到零值。但是对于三通扰动,结果表明,流需要超过25D才能达到标准要求的轮廓。为了选择标准扰动,必须进行实验研究以验证这些结果,该扰动将使用标准5167中引用的调节器进行检查,然后再开发新的流量调节器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号