Coupling efficiency equation of optical coherence tomography system with gradient refractive index rod lens is established and discussed theoretically and experimentally. The experimental result is consistent with the theoretical result. The higher coupling efficiency of optical coherence tomography system can be obtained if the θ which is the angle between mirror and y axis should be smaller than 0.5 degree.
机译:建立了光学相干层析成像系统与梯度折射率棒状透镜的耦合效率方程,并在理论上和实验上进行了讨论。实验结果与理论结果吻合。如果镜与y轴之间的夹角θ小于0.5度,则可以获得更高的光学相干断层扫描系统耦合效率。