ANALYSIS OF A CIPS STUDY FOR THE APPLICATION OF DCVG TECHNIQUE IN A 50 Km PIPELINE

机译:DCVG技术在50公里管道中的CIPS研究分析

获取原文

摘要

The CIPS technique is carried out as a proposal to find the potentials that are out of the norm NRF-047-PEMEX 2007 and not be detected by monitoring the potentials in a distance of 1000 m, even the norm NACE SP0207-2007 that applies to the procedure in CIPS technique, the ratio CIPS/DCVG depends on the measurements of CIPS. In this work, the study realized by CIPS was carried out in 50 km of pipelines identifying zones of low potential lesser than -850 mV that indicates the fault in the current demand which is higher 79.8 Amperes than the considered in the calculus for the cathodic protection systems of 36 amperes. The results shows that it is necessary to apply the CIS technique in the 64 % of the pipeline because the measurements are not in accordance with the criterion in ON state.
机译:建议使用CIPS技术,以发现超出NRF-047-PEMEX 2007规范且无法通过监视1000 m距离内的电位来检测到的电位,即使适用于NACE SP0207-2007规范也是如此。在CIPS技术的过程中,CIPS / DCVG之比取决于CIPS的测量值。在这项工作中,CIPS实现的研究是在50公里的管道中进行的,确定了低于-850 mV的低电势区域,这表明当前需求中的故障比用于阴极保护的演算中所考虑的高79.8安培。 36安培的系统。结果表明,有必要在64%的管道中应用CIS技术,因为在ON状态下测量结果与标准不符。