In this article, helically serrated finned tubes, which are generally used in heat recovery steam generator (HRSG) boilers in combined cycle power plants, are experimentally studied, in order to find their thermal contact resistance (TCR) values in different conditions. Temperature, air velocity and fin-to-tube bonding extent were the variables and a precise methodology was performed to extract the TCR values from the obtained data. The results showed that TCR decreases by increasing the air velocity and the bonding extent, but temperature has a negligible effect on it. Moreover, the TCR values showed a good consistency in order of magnitude when compared to similar systems studied before.
机译:在本文中,实验研究了螺旋锯齿状翅片管,这些管通常用于组合循环发电厂的热回收蒸汽发生器(HRSG)锅炉中,以便在不同条件下找到它们的热接触电阻(TCR)值。温度,空气速度和鳍管键合范围是变量,进行精确的方法,以从所获得的数据中提取TCR值。结果表明,通过增加空气速度和粘合程度,TCR降低,但温度对其具有可忽略的影响。此外,与之前研究的类似系统相比,TCR值显示出良好的一致性。