An embedded hardware-software Electrocardiogram platform had been conceived, were the design of the Einthoven's lead DI was been described. The system is based on the use of dry electrodes which had been set on three points of the body skin, the sensed signal fed an analog signal pre-processor to enhance its level and improve its noise immunity. The analog processor includes a typical filtering in two bands: the first band B1 is from 0.05 to 40Hz and the second B2 is from 0.05 to 150Hz. Since the analog signal approaches both the desired level and signal to noise ratio, a digital circuit based on microcontroller (AN2131QC) transforms the signal across a normalized USB bus transfer. In any cases, the embedded system could communicate in real time directly to a computer with USB port. Several data acquisition and recording file have been accomplished. Then, some processing tools have been implemented under MATLAB software as the representation of the ECG signals and its spectrum analysis for furthers offline processing.
机译:设计了嵌入式硬件软件心电图平台,并描述了Einthoven的Lead DI的设计。该系统基于使用已设置在人体皮肤三个点上的干电极,感测到的信号馈入模拟信号预处理器,以增强其电平并提高其抗噪性。模拟处理器包括两个频带的典型滤波:第一频带B1为0.05到40Hz,第二频带B2为0.05到150Hz。由于模拟信号同时接近所需的电平和信噪比,因此基于微控制器(AN2131QC)的数字电路会通过标准化的USB总线传输来转换信号。在任何情况下,嵌入式系统都可以直接与具有USB端口的计算机进行实时通信。已经完成了几个数据采集和记录文件。然后,已经在MATLAB软件下实现了一些处理工具,作为ECG信号的表示及其频谱分析,以进一步进行离线处理。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号