首页> 外文会议>2011 International Conference on Electrical Machines and Systems >Analysis of stable area of two-cell cascaded H-Bridge rectifier
【24h】

Analysis of stable area of two-cell cascaded H-Bridge rectifier

机译:两节串联H桥整流器的稳定面积分析

获取原文

摘要

In this paper, analysis of the stability in two-cell cascaded H-bridge (CHB) rectifier is presented. The stability problem is caused by the couple controllers which are used to balance the DC-link voltages of each cell. The analysis is carried on by phasorial diagram method and general conclusions about the stable area are derived. Based on the conclusions, the stable area is continued to study for a practical control scheme. The index λp is introduced to denote the unbalance degree of the two-cell rectifier. Then the stable area is defined by a group of equations. The stable area expression shows that the grid voltage, DC-link reference voltages and the expected power factor are all contributed to the stable area. Experimental results are given to verify the feasibility and validity of the proposed method.
机译:本文对两节级联H桥(CHB)整流器的稳定性进行了分析。稳定性问题是由用于平衡每个单元的直流母线电压的耦合控制器引起的。用相图法进行分析,得出有关稳定区的一般结论。根据这些结论,将继续研究稳定区域,以寻求一种实用的控制方案。引入指数λ p 来表示两节电池整流器的不平衡度。然后,稳定区域由一组方程式定义。稳定区域表达式表明,电网电压,直流母线参考电压和预期功率因数均对稳定区域有所贡献。实验结果证明了该方法的可行性和有效性。

著录项