Sensing of pH with single-use gamma sterilizable sensors is needed in single-use bioprocess components. In this study, we explored pH sensing films based on polyaniline (PANI) that were deposited onto our recently developed passive radio-frequency identification (RFID) sensors. Two main strategies for developing pH sensitive PANI films involved doping PANI with camphorsulfonic acid (CSA) and poly (styrene sulfonate) (PSS). The PANI-PSS films demonstrated the most stable response. The possibility to perform pH measurements over a range of conductivities was explored using multiple parameters of the measured resonance impedance of the RFID sensor.
机译:一次性生物过程组件需要使用一次性伽马可消毒传感器进行pH感测。在这项研究中,我们探索了基于聚苯胺(PANI)的pH感测膜,该膜被沉积在我们最近开发的无源射频识别(RFID)传感器上。开发对pH敏感的PANI膜的两种主要策略是用樟脑磺酸(CSA)和聚(苯乙烯磺酸盐)(PSS)掺杂PANI。 PANI-PSS膜显示出最稳定的响应。使用RFID传感器的测量谐振阻抗的多个参数,探索了在电导率范围内执行pH测量的可能性。