首页> 外文会议>2011 International Conference on Remote Sensing, Environment and Transportation Engineering >Determination method for Deca Brominated Diphenyl Ether in air by GC-MS
【24h】

Determination method for Deca Brominated Diphenyl Ether in air by GC-MS

机译:气相色谱-质谱法测定空气中十溴化二苯醚的方法

获取原文

摘要

This paper used an accelerated solvent extraction (ASE) in the atmosphere of a deca bromo diphenyl ether (BDE-209) for extraction. By selecting the short length, thin film capillary column, aging the capillary column particularly, improving the liner tube to optimize the conditions of the instruments, by using the high-pressure injection, setting ion to decimal places to explore appropriate analysis conditions, the Instrumental Analysis method of the atmosphere Deca Brominated Diphenyl Ether which was detected by gas chromatography - mass spectrometry was established. By implementing quality assurance and quality control (QA/QC) strictly, the method detection limit of the instrument was 9.75 ng·mL−1, quantification limit of instrument was 32.51 ng·mL−1, the standard curve linear coefficient was 0.9935, the average recovery rate was 95.37%, the precision of the method was 5.2%. Using this method to detect the two air samples in Beijing, the deca bromo diphenyl ether contents were 98.26 pg·m−3 and 67.43 pg · m−3. The experimental results show that this method can be used to analysis and detect decabromodiphenyl ether in air.
机译:本文在十溴二苯醚(BDE-209)气氛中使用加速溶剂萃取(ASE)进行萃取。通过选择短长度的薄膜毛细管柱,特别是对毛细管柱进行老化,改进衬管以优化仪器的条件,通过使用高压进样,将离子设置为小数位以探索适当的分析条件,仪器建立了用气相色谱-质谱法检测的十溴联苯醚十溴化十烷的分析方法。通过严格执行质量保证和质量控制(QA / QC),仪器的方法检出限为9.75 ng·mL -1 ,仪器的定量限为32.51 ng·mL -1 ,标准曲线线性系数为0.9935,平均回收率为95.37%,方法的精密度为5.2%。用该方法检测北京的两个空气样品,十溴二苯醚含量分别为98.26 pg·m -3 和67.43 pg·m -3 。实验结果表明,该方法可用于空气中十溴二苯醚的分析与检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信