摘要

In this paper, the experimental studies were conducted on the gas/liquid two-phase flow by using a new double-cone flowmeter with diameter ratio of 0.8 in the 50mm-diameter horizontal pipe. The discharge coefficient of the double-cone flowmeter was calibrated by experimental methods in the water standard facility. The homogeneous model and the James model were applied to measure total flowrate of the gas/liquid two-phase flow, and the measurement errors were analyzed. A modified homogeneous model was proposed. The experimental results show that relative error of the modified model is within 6%, which indicates that the new model is effective to the total flowrate measurement. At the same time, it may prove that the double-cone flowmeter can be used in gas/liquid two-phase flow measurement.
机译:在本文中,通过使用直径为0.8的水平管的直径比为0.8的新的双锥流量计在气/液两相流上进行实验研究。通过水标准设施中的实验方法校准双锥流量计的放电系数。应用均匀模型和詹姆斯模型来测量气/液两相流的总流量,分析测量误差。提出了一种改进的均匀模型。实验结果表明,修改模型的相对误差在6%范围内,这表明新模型对总流量测量有效。同时,它可以证明双锥流量计可用于气体/液体两相流量测量。