Operating performance analysis on heating conditions of large sewage source heat pump system

机译:大型污水源热泵系统供热条件运行性能分析

获取原文

摘要

This paper obtained the changing range of sewage temperature, the inlet and outlet temperatures of the sewage heat exchanger, evaporator and condenser in winter by monitoring the large sewage source heat pump system in Shi Jia-zhuang. By the testing data, the operating performance of the heat pump system was studied. During the heating test, the heat pump system operated steadily and the coefficient of heat transfer of the sewage heat exchanger was 740 W/ (m2 ·°C), and the average coefficient of performance of the heat pump was 3.76. These can be taken as references for the design and engineering application of the sewage source heat pump systems.
机译:通过监测石家庄市大型污水源热泵系统,得出了冬季污水温度的变化范围,污水热交换器,蒸发器和冷凝器的进出水温度。通过测试数据,研究了热泵系统的运行性能。在供热试验过程中,热泵系统稳定运行,污水热交换器的传热系数为740 W /(m 2 ·°C),平均热性能系数为泵为3.76。这些可以作为污水源热泵系统设计和工程应用的参考。