首页> 外文会议>Conference on image perception, observer performance, and technology assessment >Assessment of updated CAD without a new reader study:effect of calibration of computer output on the computer-aided reader performance in CADx
【24h】

Assessment of updated CAD without a new reader study:effect of calibration of computer output on the computer-aided reader performance in CADx

机译:在没有新读者的情况下评估更新的CAD:计算机输出校准对CADx中计算机辅助阅读器性能的影响

获取原文

摘要

It is very resource-demanding to assess each new version of a CAD system through a new reader study. We conjecture that the aided reader performance on a new version can be predicted by using certain characteristics of the computer output and the reader study conducted when the CAD system was initially introduced. This would likely reduce the need for additional reader studies. However, investigations are needed to develop a sound scientific foundation to test this conjecture. In this work, we consider a CADx system that outputs a disease score to aid the physician in making a diagnostic decision on a located lesion. Our major contribution is to show that calibration, reflected as a change in scale, is a characteristic of the computer output that needs to be considered in order to predict the aided reader performance in a new CADx version without a reader study. We used a bivariate bi-beta distribution to model the joint distribution of the decision variable underlying the reader without aid and the decision variable underlying the version 1 computer output in the initial version. We then applied a monotonic transformation to the computer output to simulate the computer output in a new version, i.e., the scores in the two versions differ only in calibration (specifically a change in scale). By further modeling certain mechanisms that the human reader may use for combining the computer output and the reader-alone scores, we computed the aided reader performance in terms of AUC for the new version of the CADx system. Our results show that the aided reader performance could depend on the degree of calibration difference between the two CAD system outputs. We conclude that for the purpose of predicting the aided reader performance of a new version of the CADx system, ROC performance (or any other rank-based metric) of the stand-alone CADx system may not be sufficient by itself.
机译:通过新的读者研究评估每个新版本的CAD系统非常耗资源。我们推测可以通过使用计算机输出的某些特征以及在最初引入CAD系统时进行的读者研究来预测新版本上辅助阅读器的性能。这可能会减少对其他读者研究的需求。但是,需要进行研究以建立可靠的科学基础来检验这一猜想。在这项工作中,我们考虑一个CADx系统,该系统输出疾病评分以帮助医师对所定位的病变做出诊断决策。我们的主要贡献是表明,以比例变化反映的校准是计算机输出的特征,在不进行读者研究的情况下,为了预测新的CADx版本中的辅助阅读器性能,必须考虑该输出。我们使用了一个双变量bi-beta分布来模拟读者在没有帮助的情况下所依据的决策变量与初始版本中的版本1计算机输出所依据的决策变量的联合分布。然后,我们将单调变换应用于计算机输出以模拟新版本中的计算机输出,即两个版本中的分数仅在校准方面有所不同(具体来说是比例尺的变化)。通过进一步建模人类阅读器可用于组合计算机输出和单独阅读器分数的某些机制,我们针对新版本的CADx系统,根据AUC计算了辅助阅读器的性能。我们的结果表明,辅助读取器的性能可能取决于两个CAD系统输出之间的校准差异程度。我们得出结论,出于预测新版CADx系统的辅助阅读器性能的目的,单独的CADx系统的ROC性能(或任何其他基于排名的度量标准)可能不够。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号