首页> 外文会议>ASME joint rail conference;JRC2010 >INFLUENCE OF EMBANKMENTS WITH PARAPETS ON THE CROSS-WIND TURBULENCE INTENSITY AT THE CONTACT WIRE OF RAILWAY OVERHEADS
【24h】

INFLUENCE OF EMBANKMENTS WITH PARAPETS ON THE CROSS-WIND TURBULENCE INTENSITY AT THE CONTACT WIRE OF RAILWAY OVERHEADS

机译:护坡路堤对高架接触线横风湍流强度的影响

获取原文

摘要

Winds as an environmental factor can cause significant difficulties for the railway system operation. The railway overhead has been particularly vulnerable to cross-winds related problems, such as development of undamped oscillations due to galloping phenomenon. The installation of windbreaks to decrease the aerodynamic loads on the train can affect the loads on railway overheads triggering cable galloping. One essential parameter to indicate the influence of the parapet wake on the catenary contact wire is the turbulence intensity. In this paper the results of an experimental analysis of the turbulence intensity due to the presence of parapets carried out in a wind tunnel are reported. Embankments equipped with different parapets have been tested and turbulence intensity has been measured at both contact wire locations, windward and leeward. The relative influence of the parapets is measured through a reduced turbulence intensity, defined as the ratio between the turbulence intensity measured with parapet and the turbulence intensity in the case without any parapet on the embankment. In general the reduced turbulence intensity increases as the height of the parapet increases.
机译:风作为环境因素,可能会对铁路系统的运营造成重大困难。铁路架空特别容易受到与侧风有关的问题的影响,例如由于疾驰现象而产生无阻尼振荡。安装防风林以减少火车上的空气动力学负荷可能会影响铁路高架上的负荷,从而引发电缆疾驰。表示护墙尾流对悬链接触线的影响的一个基本参数是湍流强度。在本文中,报告了由于在风洞中进行护墙而引起的湍流强度的实验分析结果。已测试了配备有不同护墙的路堤,并在接触线的两个位置(迎风和背风)测量了湍流强度。护墙板的相对影响是通过减小的湍流强度来衡量的,湍流强度是指用护墙板测得的湍流强度与路堤上没有护墙板的情况下的湍流强度之比。通常,减小的湍流强度随着护墙的高度增加而增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号