首页> 外文会议>Conference on modern technologies in space- and ground-based telescopes and instrumentation >Passive vibration isolation for SITELLE's closed cycle cooled cryostats
【24h】

Passive vibration isolation for SITELLE's closed cycle cooled cryostats

机译:Sitelle封闭循环冷却低温恒温器的被动振动隔离

获取原文

摘要

The SITELLE Imaging Fourier Transform Spectrometer system being developed by l'Université Laval at ABB-Bomemwill require two identical CCD detector systems. Our requirements for the cryogenic system for these cameras are:cooling to below 190 K, extremely low vibrational input from the cryogenic system (&1 mg RMS from 0-2 kHz), hands-offoperation over long periods of time and low original capital outlay and continued operation cost. These constraintsdrove towards the selection of a Polycold PCC cooled system which exhibits relatively low vibrational noise and canefficiently achieve the required cooling power in our target temperature range. This paper will present work performedto passively mitigate high frequency vibrations imparted by the Polycold PCC cryo-head on the detector cryostat.© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
机译:L'UniversitéAbb-Bomemwill在ABB-Bomemwill开发的Sitelle成像傅里叶变换谱仪系统需要两个相同的CCD探测器系统。我们对这些相机的低温系统的要求是:冷却至190 k以下,从低温系统(0-2 kHz的1mg rms)的极低振动输入,长时间和低原始资本支出和继续运营成本。这些约束朝向选择具有相对较低的振动噪声的多晶PCC冷却系统,并且在目标温度范围内呈现所需的冷却功率。本文将在探测器低温恒温器上的Polycold PCC Cryo-head赋予施加的高频振动,展示了执行的工作。©(2012)照片光学仪表工程师(SPIE)的版权协会。仅供个人使用的摘要下载。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号