Automated Quantification of Pulmonary Emphysema from Computed Tomography Scans: Comparison of Variation and Correlation of Common Measures in a Large Cohort

机译:计算机断层扫描扫描的自动化量化肺气肿:大队列中常用措施变化和相关性的比较

获取原文
获取外文期刊封面目录资料

摘要

The purpose of this work was to retrospectively investigate the variation of standard indices of pulmonary emphysema from helical computed tomographic (CT) scans as related to inspiration differences over a 1 year interval and determine the strength of the relationship between these measures in a large cohort. 626 patients that had 2 scans taken at an interval of 9 months to 15 months (μ: 381 days, a: 31 days) were selected for this work. All scans were acquired at a 1.25mm slice thickness using a low dose protocol. For each scan, the emphysema index (EI), fractal dimension (FD), mean lung density (MLD), and 15th percentile of the histogram (HIST) were computed. The absolute and relative changes for each measure were computed and the empirical 95% confidence interval was reported both in non-normalized and normalized scales. Spearman correlation coefficients are computed between the relative change in each measure and relative change in inspiration between each scan-pair, as well as between each pair-wise combination of the four measures. EI varied on a range of -10.5 to 10.5 on a non-normalized scale and -15 to 15 on a normalized scale, with FD and MLD showing slightly larger but comparable spreads, and HIST having a much larger variation. MLD was found to show the strongest correlation to inspiration change (r=0.85, p<0.001), and El, FD, and HIST to have moderately strong correlation (r = 0.61-0.74, p<0.001). Finally, HIST showed very strong correlation to EI (r = 0.92, p<0.001), while FD showed the least strong relationship to EI (r = 0.82, p<0.001). This work shows that emphysema index and fractal dimension have the least variability overall of the commonly used measures of emphysema and that they offer the most unique quantification of emphysema relative to each other.
机译:这项工作的目的是回顾性调查肺气肿的标准指数从螺旋计算机断层扫描(CT)扫描的变化是在1年的间隔时间与灵感的差异,并确定在一大群这些措施之间的关系的强度。 626名患者认为具有在9个月至15个月的时间间隔拍摄2次扫描(μ381天,31天)被选定为这项工作。所有扫描,在使用低剂量方案为1.25mm切片厚度获得的。对于每一个扫描中,肺气肿指数(EI),分形维数(FD),平均肺密度(MLD),和直方图(HIST)的第15百分位数进行了计算。为每个度量的绝对和相对变化计算和经验95%置信区间是在非归一化和归一秤报道两者。 Spearman相关系数被计算在每个度量的相对变化和在各扫描对之间灵感相对变化之间,以及四个措施中的每个成对组合之间。 EI上的标准化尺度上的范围上的非归一化比例-10.5至10.5,-15到15变化,与FD和MLD表示略大,但可比的价差,以及具有大得多的变化HIST。 MLD发现展现给灵感变化相关(r = 0.85,P <0.001),和El,FD和HIST相关性最强具有中等强度的相关性(r = 0.61-0.74,P <0.001)。最后,HIST显示出非常强的相关性,以EI(R = 0.92,P <0.001),而FD显示对EI的至少强相关性(r = 0.82,P <0.001)。这项工作表明,肺气肿指数和分形维数有至少变异整体肺气肿的常用的手段,他们提供相互肺气肿最独特的量化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号