Many recent studies have demonstrated the efficacy of interstitial ablative approaches for the treatment of hepatic tumors. Despite these promising results, current systems remain highly dependent on operator skill, and cannot treat many tumors because there is little control of the size and shape of the zone of necrosis, and no control over ablator trajectory within tissue once insertion has taken place. Additionally, tissue deformation and target motion make it extremely difficult to place the ablator device precisely into the target. Irregularly shaped target volumes typically require multiple insertions and several overlapping (thermal) lesions, which are even more challenging to accomplish in a precise, predictable, and timely manner without causing excessive damage to surrounding normal tissues.In answer to these problems, we have developed a steerable acoustic ablator called the ACUSITT with the ability of directional energy delivery to precisely shape the applied thermal dose . In this paper, we address image guidance for this device, proposing an innovative method for accurate tracking and tool registration with spatially-registered intra-operative three-dimensional US volumes, without relying on an external tracking device. This method is applied to guidance of the flexible, snake-like, lightweight, and inexpensive ACUSITT to facilitate precise placement of its ablator tip within the liver, with ablation monitoring via strain imaging. Recent advancements in interstitial high-power ultrasound applicators enable controllable and penetrating heating patterns which can be dynamically altered. This paper summarizes the design and development of the first synergistic system that integrates a novel steerable interstitial acoustic ablation device with a novel trackerless 3DUS guidance strategy.
机译:最近的研究已经证明了间隙消融方法治疗肝脏肿瘤的疗效。尽管这些有希望的结果,目前的系统仍然高度依赖于操作员技能,并且不能治疗许多肿瘤,因为只有对坏死区的尺寸和形状的控制,并且一旦插入就没有控制在组织内的烧蚀器轨迹。另外,组织变形和目标运动使得精确地将烧蚀器装置放置到目标中。不规则形状的靶体积通常需要多个插入和几个重叠(热)病变,这更具挑战性,以精确,可预测和及时的方式实现,而不会导致周围正常组织过度损害。 在回答这些问题时,我们开发了一种可操纵的声学消除器,称为ACUSITT,具有定向能量输送能力,精确地塑造施加的热量剂量。在本文中,我们解决了该设备的图像指导,提出了一种用于准确跟踪和工具登记的创新方法,其具有空间注册的帧内三维US卷,而不依赖于外部跟踪装置。该方法应用于柔性,蛇状,轻质和廉价的ACUSITT的引导,以便于通过应变成像进行烧蚀监测的烧蚀器尖端的精确放置。间隙高功率超声涂抹器的最新进步可实现可控和穿透的加热图案,其可以动态地改变。本文总结了第一个协同效应系统的设计和开发,该系统集成了一种具有新型轨迹无效的3DU指导策略的新型可控式间隙声消除设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号