In order to carry out comprehensive analysis and study on the application of GIS in the same frequency and phase AC voltage withstand test method, this paper studied the same frequency and phase AC voltage withstand test of GIS, briefly described the test device and the connection principle of same frequency and phase AC GIS voltage test, and analyzed the voltage variation of GIS device bus isolation switch port in detail. Hope to provide reference and help for the use of GIS equipment in AC voltage test. The traditional GIS AC voltage withstand test requires the whole performance of the power failure of adjacent to the test part and the operation part to finish it successfully. However, the same frequency and phase AC withstand voltage test of GIS refers to the same frequency and phase AC withstand voltage test of expansion or maintenance of the interval part of GIS equipment under the condition of keeping the adjacent test section and running part without power outage. Compared with the traditional test method, the test method of GIS with the same frequency and phase has some significant and outstanding advantages.
机译:为了进行全面的分析和研究GIS在相同的频率和相交流电压耐压测试方法中,本文研究了GIS的相同频率和相相电压耐受测试,简要地描述了测试装置和连接原理同样的频率和相位交流GIS电压测试,并详细分析了GIS器件总线隔离开关端口的电压变化。希望提供参考和帮助在交流电压测试中使用GIS设备。传统的GIS AC电压耐受测试需要邻近测试部件的电源故障和操作部件的整体性能,以成功完成。然而,GIS的相同频率和相位交流耐电压测试是指在保持相邻测试部分和运行部件的条件下,在保持相邻的测试部分和运行部件的条件下,相同的频率和相位交流电压测试的扩展或维护GIS设备的间隔部分。与传统的试验方法相比,具有相同频率和相位的GIS的测试方法具有一些显着且出色的优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号