The theoretical and experimental investigations of I–V characteristics of vacuum field emission array carbon microdiodes with varying temperature values on cathode are described in this paper. It is shown that increasing temperature of cathode at the permanent gap leads to the decreasing of work function of glass-like carbon. The glass-like carbon field emission array cathode with tip density N=106 cm−2 is employed.
展开▼
机译:本文描述了对阴极温度值不同温度值的真空场发射阵列碳微观的理论和实验研究。结果表明,在永久间隙处的阴极温度的增加导致玻璃状碳的工作功能的降低。采用具有尖端密度n = 10 6 sup> cm -2℃的玻璃状碳灭绝阵列阴极。