首页> 外文会议>IEEE Power and Energy Society General Meeting >Analysis of frequency extrema in the Eastern and Western Interconnections, 2010#x2013;2011
【24h】

Analysis of frequency extrema in the Eastern and Western Interconnections, 2010#x2013;2011

机译:2010 - 2011年东部互联频率辐射线分析

获取原文

摘要

Previous research into the occurrence of power system frequency extrema revealed that common patterns emerge over time. Using an existing algorithm developed for detecting and validating the extrema, we examine their occurrence in the Eastern (EI) and Western (WECC) Interconnections from January 2010 through September 2011. The results indicate that the frequency extrema continue to follow certain hourly patterns, regardless of the interconnection or year. Average weekly extrema values did not appear to have any discernible trend, while average monthly values exhibited some rough similarities from year to year. Analysis also revealed that yearly extrema averages for both the EI and WECC were almost identical for the past two years. Such information might be useful for developing operational guidelines for grid dispatchers.
机译:以前的电力系统频率发生的研究显示普通模式随着时间的推移出现。使用开发用于检测和验证极值的现有算法,我们从2010年1月到2011年1月的东部(EI)和Western(WECC)互连中的发生。结果表明,频率极值继续遵循某些每小时模式,无论如何互连或年度。平均每周极值值似乎没有任何可辨别的趋势,而平均每月价值观从一年到一年中表现出一些粗略的相似之处。分析还透露,在过去两年中,EI和WECC的年极值平均几乎相同。此类信息可能很有用,以开发网格调度员的操作指南。