首页> 外文会议>2010 IEEE International Conference on Progress in Informatics and Computing >Evaluation of T wave alternans detectors based on a simulation study
【24h】

Evaluation of T wave alternans detectors based on a simulation study

机译:基于仿真研究的T波交替传感器的评估

获取原文

摘要

A simulation study of T wave alternans (TWA) is proposed in order to evaluate the performance of typically used TWA detectors, as well as to quantify the performance characteristics in terms of sensitivity, positive predictivity and beat-to-beat amplitude estimation accuracy. ECG signals are simulated repeating a single beat, and adding mixed noise from 4 different noise sources at different levels. TWA episodes with different amplitudes and waveforms were added to the signals. We can conclude from this study that the correlation-based detector obtained much lower detection rates than the other detectors, especially in sensitivity for low amplitude TWA. The amplitude accuracy in the detected episodes was also found to be the worst with correlation-based detector. The other detectors have shown a similar behavior. However, the complex demodulation detector needs a much higher computational complexity. In general, alternans are detected with rates near 100% for SNR greater than 10 dB for physiological noise sources.
机译:提出了一种模拟T波障碍(TWA)的研究,以评估通常使用的TWA探测器的性能,以及在灵敏度,阳性预测性和搏动幅度估计精度方面量化性能特征。 ECG信号被模拟重复单个节拍,并在不同级别添加4个不同噪声源的混合噪声。向信号添加具有不同幅度和波形的TWA剧集。我们可以从该研究中得出结论,基于相关的探测器比其他探测器的检测率大得多,尤其是低振幅TWA的灵敏度。还发现检测到的剧集中的幅度精度是基于相关的探测器的最糟糕的。其他探测器已经显示出类似的行为。然而,复杂的解调检测器需要更高的计算复杂度。通常,对于生理噪声源的SNR大于10dB的SNR,用率接近100%的速率检测备率。