首页> 外文会议>2010 International Power Electronics Conference >Improvement of output dynamic performance of an Average Current Mode Controlled buck converter with a parallel controller
【24h】

Improvement of output dynamic performance of an Average Current Mode Controlled buck converter with a parallel controller

机译:具有并联控制器的平均电流模式控制降压转换器的输出动态性能的改善

获取原文

摘要

This paper presents a parallel voltage controller to improve the output dynamic performance of a buck converter with Average Current Mode Control (ACMC). The parallel controller is a high-order controller synthesized from parallel connection of the two basic controllers. It is proposed to compensate the control-to-output transfer function of the converter, which has multiple poles and zeros. Up until now, the task is commonly performed by the two-pole one-zero controller, which is clearly not adequate and has somewhat limited the dynamic performance of the converter. In the paper, the design of parallel controller is illustrated with a 5V/2V ACMC buck converter. Experimental and simulated results that show the improvement of output voltage response to a step load change are presented.
机译:本文介绍了一个平行电压控制器,提高了平均电流模式控制(ACMC)的降压转换器的输出动态性能。并联控制器是从两个基本控制器的并行连接合成的高阶控制器。建议补偿转换器的控制到输出传递函数,其具有多个杆和零。到目前为止,任务通常由双极单零控制器执行,这显然不足,并且有一些限制了转换器的动态性能。本文用5V / 2V ACMC降压转换器示出了并联控制器的设计。呈现了对阶梯负荷变化的输出电压响应的提高的实验和模拟结果。