摘要

In the research of EPA temperature transducer, Platinum temperature-resistance is used as forward transducer input. Because standard format of R-t is a quartic equation on t when temperature is between -200 and 0 centigrade, a suitable method must be found so that we can calculate the temperature value online. On the same time, this method should be easy to realize and fit to be applied in embedded environment. So in this article, a new analytic method will be argued, which bases on the theory of quartic equation with one known and cubic equation with one known. The calculation result is compared with Newton's method and the error is analyzed through MATLAB. It is proved that this analytic method has no model error and the time for calculating is fixed and it can also be applied in similar fields if necessary.
机译:在EPA温度传感器的研究中,铂金电阻被用作传感器的正向输入。由于R-t的标准格式是温度在-200到0摄氏度之间时t的四次方程,因此必须找到合适的方法以便我们可以在线计算温度值。同时,该方法应易于实现并适合在嵌入式环境中应用。因此,在本文中,将提出一种新的解析方法,该方法基于具有一个已知的四次方程和具有一个已知的三次方程的理论。将计算结果与牛顿法进行比较,并通过MATLAB对误差进行分析。实践证明,该分析方法无模型误差,计算时间固定,必要时也可应用于类似领域。