Shear Strength Effects of Multiaxial Glass Fiber Sheets for Pultruded FRP Connection

机译:多轴玻璃纤维板对拉挤FRP连接的剪切强度效应

获取原文

摘要

This paper experimentally investigates the strengtheningeffects of different types of GF sheets with different numbersof GF sheet layers. The failure modes of specimens changeafter strengthening with GF sheets. While shear-out failuresoccur on the whole thickness of PFRP members in nonstrengthenedspecimens, combine failures occur instrengthened specimens with shear-out failure in roving partsand bearing failures in CSM and GF sheets. GF sheets canincrease effectively the bolted connection strengths of PFRPmembers and the strengthening effects depend on the numbersof GF sheet plies. 2-ply GF sheets have better strengtheningeffects than 4-ply GF sheets if considering the strengtheningeffects per thickness unit.
机译:本文实验研究了加强不同类型的不同类型GF纸张的影响GF薄片层。标本变化的失败模式通过GF纸张加强。剪切失败发生在非强行的整体厚度的PFRP成员标本,结合失败发生在加强粗纱剪切失效的标本CSM和GF纸张中的轴承故障。 gf床单可以有效地增加了PFRP的螺栓连接强度成员和加强效果取决于数字GF薄板层。 2层GF薄片具有更好的加强如果考虑到强化,效果比4层GF纸张每个厚度单元的效果。