首页> 外文会议>ASME international mechanical engineering congress and exposition;IMECE2008 >INVESTIGATION ON THERMAL PERFORMANCE OF PRIMARY AND SECONDARY THERMOELECTRIC MODULES
【24h】

INVESTIGATION ON THERMAL PERFORMANCE OF PRIMARY AND SECONDARY THERMOELECTRIC MODULES

机译:初级和次级热电模块的热性能研究

获取原文

摘要

This paper reports the findings of an investigation on application of secondary thermoelectric (TE) module as a heat exchanger for the primary TE module. The experimental system consists of two commercially available thermoelectric modules arranged thermally in series with a heat sink and an integrated circuit (IC) chip. Heat produced from the IC chip is transferred to the heat sink via the TE modules. A total of nine experimental setups were analyzed using measured temperature data to assess the efficacy of the setups.Experimental evidence shows that the secondary TE module provides additional cooling advantage. The cooling capacity for a system with secondary TE module is 10.95W compared to 3.5W for systems where secondary modules are non-existent. The respective coefficient of performance.COP = Q_c/Q_p are 2.43 and 0.78. The use of asecondary TE module as a heat exchanger for the primary thermoelectric module is ineffective when compared with liquid-cooled heat exchanger.Results further showed that during early stages of heating and cooling processes, there exists lag in response time between the integrated circuits chip. This could result in over-heating or under-cooling the IC chip.
机译:本文报告了将二次热电(TE)模块用作一次TE模块的热交换器的调查结果。该实验系统由两个与散热器和集成电路(IC)芯片热串联排列的市售热电模块组成。从IC芯片产生的热量通过TE模块传递到散热器。使用测得的温度数据对总共九个实验装置进行了分析,以评估装置的功效。 实验证据表明,辅助TE模块提供了额外的冷却优势。具有辅助TE模块的系统的冷却能力为10.95W,而没有辅助模块的系统的冷却能力为3.5W。各自的性能系数。 COP = Q_c / Q_p为2.43和0.78。使用一个 与液冷换热器相比,作为主热电模块换热器的二次TE模块无效。 结果还表明,在加热和冷却过程的早期阶段,集成电路芯片之间的响应时间存在滞后。这可能会导致IC芯片过热或过冷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号