首页> 外文会议>ASME summer bioengineering conference;SBC2009 >COMPARISON OF CORTICAL AND CANCELLOUS SCREWS FOR STERNAL FIXATION
【24h】

COMPARISON OF CORTICAL AND CANCELLOUS SCREWS FOR STERNAL FIXATION

机译:硬骨螺钉和松骨螺钉的比较

获取原文

摘要

The goal of this study is to compare the performance of currently available screw types and configurations for rigid sternal fixation. Bone fixation plates were attached to osteoporotic human sternum with cortical or cancellous screws in either a unicortical or bicortical manner. The plates were cyclically loaded transversely (0-50N at 2Hz) for 15,000 cycles; the resulting lateral screw displacement was measured continuously. Bicortical attachment allowed significantly lower initial displacement than unicortical (p=0.015), whereas cortical screws allowed significantly lower displacement than cancellous screws after long term cycling (p= 0.039). These initial findings indicate that both screw type and cortical purchase are important parameters in the design of a rigid plating system for sternal closure. Cortical screws appear to be more applicable to the osteoporotic sternum, as the cortical shell regions support more screw purchase than the degenerated cancellous part, and bicortical screw purchase appears to decrease screw loosening.
机译:这项研究的目的是比较用于刚性胸骨固定的当前可用螺钉类型和配置的性能。用皮质或松质骨螺钉以单皮质或双皮质方式将骨固定板附着于骨质疏松性人的胸骨上。将板横向横向加载(0Hz至2Hz下为0-50N),持续15,000个循环。连续测量所得的横向螺钉位移。双皮质连接的初始位移远低于单皮质(p = 0.015),而长期循环后,皮质螺钉比松质螺钉的位移低得多(p = 0.039)。这些初步发现表明,螺钉类型和皮质采购都是在胸骨闭合硬质钢板系统设计中的重要参数。皮质螺钉似乎更适用于骨质疏松性胸骨,因为皮质外壳区域比退化的松质部分支持更多的螺钉购买,而双皮质螺钉的购买似乎可以减少螺钉松动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号