首页> 外文会议>World environmental and water resources congress >Kansas City, MO Overflow Control Program: Line Creek/Rock Creek Sanitary Sewer Study
【24h】

Kansas City, MO Overflow Control Program: Line Creek/Rock Creek Sanitary Sewer Study

机译:密苏里州堪萨斯城溢流控制计划:Line Creek / Rock Creek卫生下水道研究

获取原文

摘要

Kansas City’s Water Services Department (WSD) prepared a Long Term Control Plan(LTCP) to provide a roadmap to reduce the magnitude, frequency, and duration ofcombined sewer overflows (CSOs), and for the rehabilitation and improvement of thesanitary sewer system (SSS) to prevent sanitary sewer overflows (SSOs) and basementbackups.The study area for this project includes the sanitary sewer system within the LineCreek, Rock Creek, Buckeye Creek, and Searcy Creek watersheds. The drainage areaof these watersheds is approximately 25 square miles north of the Missouri River andcontain 8-in to 72-in diameter sanitary sewers.A hydraulic model was developed using XP-SWMM based on data collected from theCity’s Geographical Information System. Recommended improvements wereevaluated to prevent SSOs, and preliminary cost estimates were developed.
机译:堪萨斯市水务局(WSD)制定了长期控制计划 (LTCP),以提供路线图以减少震荡的幅度,频率和持续时间 下水道溢流(CSO),以及污水处理厂的修复和改善 防止下水道溢水(SSO)和地下室的下水道卫生系统(SSS) 备份。 该项目的研究区域包括生产线内的下水道系统 溪,洛克溪,七叶树溪和塞西溪分水岭。排水面积 这些流域位于密苏里河以北约25平方英里, 包含直径8英寸至72英寸的下水道。 基于XP-SWMM的水力模型是根据从水库收集的数据开发的。 市的地理信息系统。推荐的改进是 进行评估以防止SSO,并制定了初步成本估算。