High flux dialysis the first choice of therapy for hemodialysis patients within the last decade due to its clinical outcome. In this study the effect of dialysis environment on the mechanical and structural stability of high flux dialyzers containing polysulfone membranes were investigated. Dialysis sessions were performed on a certain group of patients with dialysis ages less than two years and without any other accompanying disease. Mechanical data and XRD results revealed the differences in material characteristics between virgin and used membranes obtained from polysulfone membranes. With the help of tensile tests it was shown that the mechanical properties used membranes were reduced in terms of ultimate tensile strength. XRD experiments revealed that the degree of crystallinity of the polysulfone dialysis membranes were raised. It was concluded that high flux dialyzer membranes are becoming more brittle and having more crystallinity after dialysis session. By this way the membranes are more prone to mechanical defects during dialysis. The degree of crystallinity increases under cyclic loading which resembles the changing of the pump speed or transmembrane pressure during dialysis in case of clinical situations like hypotension during dialysis. This issue is very important for dialysis centers performing reuse procedures for dialysis centers, because any damage to dialysis membranes would cause very serious clinical complications.
机译:高通量透析由于其临床结果,在过去十年中是血液透析患者的首选治疗方法。在这项研究中,研究了透析环境对含有聚砜膜的高通量透析器的机械和结构稳定性的影响。在某些年龄小于2岁且没有其他伴随疾病的患者中进行透析。力学数据和XRD结果表明,从聚砜膜获得的原始膜和用过的膜在材料特性上存在差异。借助于拉伸试验表明,所用膜的机械性能在极限拉伸强度方面降低了。 XRD实验表明聚砜渗析膜的结晶度提高。结论是透析后高通量透析膜变得更脆并且具有更大的结晶度。通过这种方式,膜在透析过程中更容易出现机械缺陷。在循环载荷下,结晶度增加,类似于在透析过程中发生低血压等临床情况下,透析过程中泵速或跨膜压力的变化。对于透析中心执行透析中心的重复使用程序,此问题非常重要,因为对透析膜的任何损坏都会引起非常严重的临床并发症。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号