首页> 外文会议>Advances in powder metallurgy particulate materials - 2009 >Preliminary Results for HIP Bonding Ta to W Targets for the Materials Test Station
【24h】

Preliminary Results for HIP Bonding Ta to W Targets for the Materials Test Station

机译:材料测试站将Ta与W靶材HIP键合的初步结果

获取原文

摘要

Tungsten targets for the Materials Test Station (MTS) were clad with thin tantalum cover plates and a tantalum frame using hot isostatic pressing (HIP). A preliminary HIP parameter study showed good bonding and intimate mechanical contact for Ta cover plate thicknesses of 0.25 mm (0.010inch) and 0.38 mm (0.015 inch). HIP temperatures of full HIP runs were 1500°C (2732°F). HIP pressure was 203 MPa (30 ksi).
机译:材料测试站(MTS)的钨靶被覆有薄的钽盖板和采用热等静压(HIP)的钽框架。初步的HIP参数研究表明,Ta盖板的厚度为0.25 mm(0.010英寸)和0.38 mm(0.015英寸)时,具有良好的粘合性和紧密的机械接触。整个HIP运行的HIP温度为1500°C(2732°F)。 HIP压力为203 MPa(30 ksi)。