首页> 外文会议>11th International Conference on Electrostatic Precipitation(第11届国际电除尘学术会议)论文集 >Experimental Investigation on Styrene Emission with a 1000m3/h Plasma System
【24h】

Experimental Investigation on Styrene Emission with a 1000m3/h Plasma System

机译:1000m3 / h等离子体系统中苯乙烯排放的实验研究

获取原文

摘要

This paper reports experimental investigations on plasma-induced styrene emission abatement in air at room temperature (24±2°C) and pressure. Tests were performed with a 1000 m3/h plasma system under DC corona discharge. It is observed that styrene destruction in DC glow discharge is negligible in contrast to streamer corona. When relative humidity (RH) is in the range of 30%-80%, the energy consumption for styrene decomposition rises with RH value. The energy coefficient β value becomes larger with increasing either RH or the initial styrene concentration for RH in 30%-80% and the concentrations within 90 ppm-1000 ppm,respectively, With regards to those dependence sensitivity, the lower the concentration, the more sensitive to the RH value. Under optimal condition (100 ppm initial concentration, 35 %RH), the β value is 18.73 J/L.
机译:本文报道了在室温(24±2°C)和压力下空气中等离子体诱导的苯乙烯排放减少的实验研究。在直流电晕放电条件下,使用1000 m3 / h等离子体系统进行测试。观察到,与流光晕电晕相比,直流辉光放电中的苯乙烯破坏可忽略不计。当相对湿度(RH)在30%-80%的范围内时,苯乙烯分解的能耗随着RH值而增加。能量系数β值分别随RH或RH的初始苯乙烯浓度的增加(30%-80%)和浓度在90 ppm-1000 ppm之内而增大,关于那些依赖性灵敏度,浓度越低,对RH值敏感。在最佳条件下(初始浓度100 ppm,相对湿度35%),β值为18.73 J / L。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号