We realized new adaptive holographic sensor and interferometer, which allows to visualize high-resolution 3D images of diffuse reflected objects in Continue Hologram Registration Regime- CHRR. The coupled laser wave nonlinear theory was applied for optimization of hologram recording in crystals symmetry 23 and optimized experimental set up. Experimentally demonstrated dynamical holographic image sensors on doped 23 symmetry photosensitive crystals, with resolution 7900-lines/mm at 632 nm and 11641 lines/mm at 440 nm for 15 mW CW HeNe and He-Cd lasers. The results are presented for holographic visualization of Cryogenic and Ultrasonic near field images of Surgical Medical Instrument. Application of CHRR interferometer for hologram registration of moving biological object in "vivo" is illustrated.
机译:我们实现了新的自适应全息传感器和干涉仪,可以在连续全息图配准系统CHRR中可视化漫反射物体的高分辨率3D图像。应用耦合激光非线性理论对晶体对称性为23的全息图记录进行了优化,并建立了优化的实验装置。实验证明,在掺杂的23种对称光敏晶体上具有动态全息图像传感器,对于15 mW CW HeNe和He-Cd激光器,其在632 nm处的分辨率为7900线/ mm,在440 nm处的分辨率为11641线/ mm。结果被提供用于外科医疗器械的低温和超声近场图像的全息可视化。举例说明了CHRR干涉仪在“活体内”移动生物物体的全息图配准中的应用。