In the basic performance of SF6 high voltage circuit breaker, the breaking performance is the most important technical index to measure the performance of the product, and the breaking performance is mainly depended on the recovery characteristic of the dielectric strength for the arc extinguishing chamber during the opening and breaking process of the circuit breaker. In this paper, based on the theory of gas dynamics and electromagnetic field, the flow characteristics of the air flow and electric field intensity in the arc extinguishing chamber are simulated by the computer simulation software. And a numerical calculation method for the dielectric strength recovery characteristic of the circuit breaker is proposed. The method presented in this paper will provide necessary theoretical basis and technical support for the future application of the SF6 high voltage circuit breaker in high voltage system.
机译:在SF6高压断路器的基本性能中,断裂性能是测量产品性能的最重要的技术指标,并且断裂性能主要取决于灭弧室期间的介电强度的恢复特性断路器的打开和破碎过程。本文基于气体动力学理论和电磁场,通过计算机仿真软件模拟了灭弧室中的空气流和电场强度的流动特性。提出了一种用于断路器电介质强度恢复特性的数值计算方法。本文提出的方法将为SF6高压断路器在高压系统中提供必要的理论基础和技术支持。