Neutral displacement overvoltage is harmful to power equipment. A method for suppressing the neutral point displacement overvoltage and its suppression circuit were proposed in this paper to restore it to a normal level. First, it is judged if the neutral point displacement voltage is greater than the set value. Next, the previous and current currents on the arc suppression coil are measured. Then, current is injected at the neutral point of the grid. Finally, it is judged whether the zero-sequence overvoltage of the distribution network is successfully suppressed. The feasibility of the suppression method and the suppression circuit proposed in this paper was proved by the experimental results. This method is great significance for suppressing the displacement overvoltage of the neutral point of the distribution network.
机译:中性位移过压对电力设备有害。提出了一种抑制中性点位移过电压及其抑制电路的方法,以将其恢复到正常水平。首先,判断中性点位移电压是否大于设定值。接下来,测量电弧抑制线圈上的先前和电流电流。然后,在网格的中性点注入电流。最后,判断是否成功抑制了分发网络的零序过压的零序过电压。通过实验结果证明了本文提出的抑制方法和抑制电路的可行性。该方法对于抑制分配网络的中性点的位移过电压是具有重要意义。