The deployment of multimedia data transmission is increasing, Digital Subscriber Line technology (xDSL) and other systems are widely used on the telecommunication access network. Conveying such services requires higher data rates, consequently higher bandwidths, and operating frequencies. So, the modelling of the cables is essential to study the disturbing electromagnetic phenomena. Analytical expressions for P.U.L. parameters of finite length twisted pair lines are derived, and verified by the measurement in this paper. These expressions give the capacitances and the inductances values in every point of the cable.
机译:多媒体数据传输的部署正在增加,数字用户线技术(xDSL)和其他系统已广泛用于电信访问网络。传送此类服务需要更高的数据速率,因此需要更高的带宽和工作频率。因此,电缆的建模对于研究电磁干扰现象至关重要。 P.U.L.的分析表达式推导了有限长双绞线的参数,并通过测量验证。这些表达式给出了电缆每个点的电容和电感值。