Partial Discharge Impulse Behaviour in Different Insulating Media

机译:不同绝缘介质中的局部放电脉冲行为

获取原文

摘要

Partial discharge detection is an effective method for monitoring and evaluation of dielectric condition of high voltage equipment and so an important part for technical diagnostic as the base for condition based maintenance. A variety of different techniques is available to detect the partial discharge activity. The measurements are carried out with electrical, acoustical, optical and chemical techniques. Beside the detection of the individual partial discharge impulse and its impulse behaviour with the conventional electrical methods, the exact localization of the partial discharges is very important for an efficient maintenance. Therefore unconventional methods, for example the acoustical or the optical detection, are in use. In a research project an optical partial discharge measurement system was developed. In this paper a comparison between the optical and the conventional electrical measurement system is carried out for different insulation media at a peak-plate arrangement.
机译:局部放电检测是一种用于监视和评估高压设备介电状况的有效方法,因此是进行技术诊断的重要部分,是基于状况进行维护的基础。可以使用多种不同的技术来检测局部放电活动。使用电气,声学,光学和化学技术进行测量。除了利用常规的电气方法检测单个局部放电脉冲及其脉冲行为外,局部放电的精确定位对于有效维护也非常重要。因此,正在使用非常规方法,例如声学或光学检测。在一个研究项目中,开发了光学局部放电测量系统。在本文中,在峰板布置下针对不同的绝缘介质,对光学测量系统和常规的电气测量系统进行了比较。