This paper investigates the impact of input voltage unbalance and sags on stresses in the dc bus choke inductor and dc bus electrolytic capacitors of adjustable-speed drives (ASDs). These stresses are primarily attributable to the rectifier's transition into single-phase operation, giving rise to low-order harmonic voltages (120 Hz, 240 Hz, etc.) that are applied to the dc link filter components. These harmonics elevate the ac flux densities in the dc choke core material significantly above values experienced during normal balanced excitation conditions, causing additional core losses and potential magnetic saturation of the core. It is shown that the effects of voltage unbalances and sags on the dc link capacitor lifetime is the same when either line inductors or a dc link choke inductor are used if the dc choke inductance value is twice the value of the line inductance. Simulations and experimental tests are used to verify the accuracy of predictions provided by closed-form analysis and simulation for a 5 hp ASD system.
机译:本文研究了输入电压不平衡和骤降对可调速驱动器(ASD)的直流母线扼流电感器和直流母线电解电容器中的应力的影响。这些应力主要归因于整流器过渡到单相运行,从而引起施加到直流链路滤波器组件的低阶谐波电压(120 Hz,240 Hz等)。这些谐波使直流扼流圈磁芯材料中的交流磁通密度大大提高,超过正常平衡励磁条件下的交流磁通密度,从而导致额外的磁芯损耗和磁芯的潜在磁饱和。结果表明,如果使用直流电感或直流扼流电感,则当直流扼流电感值是线路电感值的两倍时,电压不平衡和骤降对直流环节电容器寿命的影响是相同的。仿真和实验测试用于验证5 hp ASD系统的闭式分析和仿真所提供的预测的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号