首页> 外文会议>Infrared and Millimeter Waves, 2004 and 12th International Conference on Terahertz Electronics, 2004. Conference Digest of the 2004 Joint 29th International Conference on >Millimeter wave imaging diagnostic for simultaneous density and temperature fluctuation measurements on the TEXTOR Tokamak
【24h】

Millimeter wave imaging diagnostic for simultaneous density and temperature fluctuation measurements on the TEXTOR Tokamak

机译:毫米波成像诊断可同时在TEXTOR Tokamak上进行密度和温度波动测量

获取原文

摘要

A millimeter wave imaging diagnostic for simultaneous density and temperature fluctuation measurements has been developed for operation on the TEXTOR Tokamak. The system is based on the quasi-optical imaging of the radiation from the plasma onto state-of-the-art millimeter wave mixer/receiver arrays. The temperature (fluctuation) measurements are based on the observation of electron cyclotron emission from a 2D plasma area with 8/spl times/16 sample volumes of about 1 cm/sup 3/. The density fluctuation measurements are based on active probing by means of reflectometry. In this case reflections from 16 sample volumes, arranged along the cutoff surfaces are diagnosed. The combined millimeter wave imaging diagnostic offers distinct advantages above the commonly used non-imaging diagnostics.
机译:已经开发出用于同时密度和温度波动测量的毫米波成像诊断,用于在Texor Tokamak上进行操作。该系统基于从等离子体的辐射到最先进的毫米波混合器/接收器阵列的准光学成像。温度(波动)测量基于从2D等离子体区域的电子回流发射的观察,其中8 / SPL时间/ 16样品体积为约1cm / sup 3 /。密度波动测量基于借助于反射仪的主动探测。在这种情况下,沿着截止表面排列的16个样品的反射被诊断出来。组合的毫米波成像诊断提供了优于常用的非成像诊断的明显优势。