Directly buried installation without expansion joint is a better layout to municipal heat-supply system of heat and power cogeneration. We carefully tested stress in partly restrained section (PRS), the diameter of which are DN600~700. The paper briefly introduces test project and methods; brings forward calculation formula of stress distribution, length of PRS, magnitude of expansion and contraction and average friction force factor. The results of the experimentation leads to establishment of the following proportional relationships: (1) L∝ΔT~(0.5), (2) L∝1/h, (3) ΔL ∝ΔT~(1.5), (4) ΔL∝1/h, (5) μ ∝ ΔT~(0.5) , (6) μ∝S, (7) μ∝Δ1/Dc; where L is length of PRS, ΔT is the difference in temperature, h is the distance between pipe and ground surface, ΔL is the magnitude of expansion and contraction, μ is the average friction force factor, S is pipe-sectional area, DC is insulating pipe's outside diameter.
机译:不带伸缩缝的直接埋地安装是热电联产的市政供热系统的更好布局。我们仔细测试了直径为DN600〜700的部分约束区域(PRS)的应力。简要介绍了测试项目和方法。提出了应力分布,PRS长度,伸缩幅度和平均摩擦力因子的计算公式。实验结果导致建立以下比例关系:(1)L∝ΔT〜(0.5),(2)L∝1 / h,(3)ΔL∝ΔT〜(1.5),(4)ΔL∝ 1 / h,(5)μΔT〜(0.5),(6)μS,(7)μΔ1/ Dc;其中L是PRS的长度,ΔT是温度差,h是管道与地面之间的距离,ΔL是膨胀和收缩的大小,μ是平均摩擦力因数,S是管道截面积,DC是绝缘管的外径。