This paper aims to the detection of stator winding inter-turn short circuit fault in induction motors. Firstly, the numerical simulation of stator winding inter-turn short circuit fault is accomplished. Secondly, this paper points out that the stator winding apparent impedance angle can be viewed as the fault feature, and moreover, the lagging stator winding, adjacent to the faulty stator winding with inter-turn shorts, possesses the largest apparent impedance angle variation among the 3-phase stator windings, as allows to identify the faulty stator winding. Finally, the relevant experiments have been carried out, and the results obtained clearly validate the detection strategy. The further work will focus on refining the detection strategy and applying it to the industrial site.
机译:本文旨在检测感应电动机中的转向间隙短路故障的定子绕组。首先,完成了定子绕组匝间短路故障的数值模拟。其次,本文指出,定子绕组表观阻抗角可以被视为故障特征,而且,滞后定子绕组,靠近具有匝间短路的故障定子绕组,具有最大的表观阻抗角度变化3相定子绕组,允许识别故障定子绕组。最后,已经进行了相关实验,并获得了结果明确验证了检测策略。进一步的工作将专注于炼制检测策略并将其应用于工业部位。