LOW-PRESSURE TURBINE SEPARATION CONTROL - COMPARISON WITH EXPERIMENTAL DATA

机译:低压汽轮机分离控制-与实验数据的比较

获取原文

摘要

The present work details a computational study, using the Glenn-HT code, that analyzes the use of vortex generator jets (VGJs) to control separation on a low-pressure turbine (LPT) blade at low Reynolds numbers. The computational results are also compared with the experimental data of Bons et al. [1] for steady VGJs. It is found that the code determines the proper location of the separation point on the suction surface of the baseline blade (without any VGJ) for Reynolds numbers of 50,000 or less. Also, the code finds that the separated region on the suction surface of the blade vanishes with the use of VGJs. However, the separated region and the wake characteristics are not well predicted. The wake width is generally over-predicted while the wake depth is under-predicted.
机译:本工作详细介绍了使用Glenn-HT代码进行的计算研究,该研究分析了涡旋发生器射流(VGJ)的使用,以控制低雷诺数下的低压涡轮(LPT)叶片上的分离。计算结果也与Bons等人的实验数据进行了比较。 [1]用于稳定的VGJ。发现对于50,000或更小的雷诺数,该代码确定了分离点在基准叶片的吸力表面(没有任何VGJ)上的正确位置。此外,该代码还发现,使用VGJ,叶片吸力表面上的分离区域消失了。但是,分离区域和唤醒特性不能很好地预测。尾流宽度通常被高估,而尾流深度则被低估。