This paper aims to reveal ESD event that is usually overlooked during HGA dynamic test operation and how a solution to the problem has been established. Experiments were conducted to determine a hidden ESD source by using two different designs of dynamic test shoe. ESD events were captured during unloading and reloading of HGA BFC pad to the old shoe fixture (original design). Tribocharging and field-induced charging are both suspects in the observed failures. These results are consistent with CDM type ESD failure. Results show how this event caused severe magnetic or melting damage to the GMR sensor. We were able to measure of about 155 volts (negative charge) on BFC kapton after unloading from the old shoe DET fixture. Our fast digital oscilloscope captured 131.2 mA (max) at 1 nanosecond current transients during metal contact of MR exposed lead. This causes a great yield loss at HSA level manufacturing for that particular prototype program.
机译:本文旨在揭示在HGA动态测试操作中通常被忽略的ESD事件,以及如何确定问题的解决方案。通过使用两种不同的动态测试靴设计来进行实验以确定隐藏的ESD源。在将HGA BFC垫卸载和重新加载到旧鞋夹具(原始设计)期间捕获了ESD事件。摩擦充电和现场感应充电都是观察到的故障的可疑因素。这些结果与CDM类型的ESD故障一致。结果显示此事件如何对GMR传感器造成严重的磁性或熔化损坏。从旧的鞋子DET固定装置上卸下后,我们能够在BFC武器上测量约155伏(负电荷)。我们的快速数字示波器在MR暴露的导线与金属接触期间,在1纳秒的瞬态电流下捕获了131.2 mA(最大值)。对于该特定的原型程序,这会在HSA级别的制造中造成很大的产量损失。