首页> 外文会议>European Test Workshop, 2000. Proceedings. IEEE >Comparison of defect detection capabilities of current-based and voltage-based test methods
【24h】

Comparison of defect detection capabilities of current-based and voltage-based test methods

机译:基于电流和基于电压的测试方法的缺陷检测能力的比较

获取原文

摘要

The industrial default to test random logic is based on stuck-at fault test patterns applied via scan-chains. This test-method can be described as static voltage testing. A second well-known method is I/sub DDQ/ resting, which can be described as static current testing. This second method is especially suited for detecting resistive shorts. For deep sub-micron technologies new defect mechanisms start to become important. Especially, opens are a much feared type of defect since static test methods are less suited to detect these defects. Dynamic test methods such as delay-fault testing and transient current testing could fill this gap in the test suite. The paper gives an overview of the aforementioned test-methods including some of the new current-based test methods necessary for deep submicron technologies and their defect detection capabilities.
机译:用于测试随机逻辑的工业默认值基于通过扫描链应用的固定故障测试模式。该测试方法可以描述为静态电压测试。第二种众所周知的方法是I / sub DDQ / resting,它可以描述为静态电流测试。第二种方法特别适合于检测电阻性短路。对于深亚微米技术,新的缺陷机制​​开始变得重要。特别是,开孔是一种非常令人担忧的缺陷类型,因为静态测试方法不太适合检测这些缺陷。诸如延迟故障测试和瞬态电流测试之类的动态测试方法可以填补测试套件中的空白。本文对上述测试方法进行了概述,其中包括深亚微米技术及其缺陷检测能力所必需的一些新的基于电流的测试方法。