Comparison of site-to-site measurement reproducibility using UK National Physical Laboratory and Austrian Research Center test sites as a reference

机译:使用英国国家物理实验室和奥地利研究中心测试站点作为参考进行站点到站点测量可重复性的比较

获取原文

摘要

Twenty Radiated emission sites are compared using a sinusoidal reference transmitter in the frequency range of 30 to 1000 MHz. The data is referenced to results measured on the UK National Physical Laboratory and Austrian Research Centers reference sites. The data on nineteen site is reported in this article, the data on the one remaining was done at three meters and not comparable. Of the nineteen sites, nine performed from four to six measurements on different days and usually with different people. Statistically, the results of these nine sites show 95% of the measurements made were within +/-2.1 dB from the average of the reference sites. Test result differences in repeated EMC tests are partially caused by physical characteristics of the measurement sites and changes or differences in the measurement chain. This program has met the requirements of A2LA and NVLAP for site-to-site comparisons. Being programmable the source could be easily adaptable to "blind" proficiency assessments.
机译:使用正弦参考发射器在30至1000 MHz的频率范围内比较了二十个辐射发射点。数据参考在英国国家物理实验室和奥地利研究中心参考站点上测得的结果。本文报告了十九个站点的数据,其余一个站点的数据是在三米处完成的,无法比较。在这19个站点中,有9个站点在不同的日子(通常是由不同的人)进行了4到6次测量。从统计上讲,这9个位置的结果表明,所进行的95%的测量值均与参考位置的平均值相差+/- 2.1 dB。重复EMC测试中的测试结果差异部分是由测量位置的物理特性以及测量链中的变化或差异引起的。该程序已满足A2LA和NVLAP进行站点到站点比较的要求。通过编程,源可以轻松适应“盲”能力评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号