Nowadays the corrosion of reinforcement is the most harmful damage that can occur in refinforced concrete structures. The case study is one analysis form utilized for to verify the damages evolution when the structure is exposed in environment. In a residential building located at saline environment in Brazil was made measures of carbonation depth, chloride ions and to apply an new assessment method for to establish quantitatives boundaries for structures degradation. The results showed that the carbonation depth was smaller than concrete cover, but the amount of chloride ions in structural elements was biggest than the threshold vlaue. The structure deterioration and immediate intervention on structure for to restore the serviceability levels. So, this work show make real the possibility of to verify the damages evolution in a structure, using simple inspection procedures with a numeric analysis.
机译:如今,钢筋的腐蚀是在钢筋混凝土结构中可能发生的最有害的破坏。案例研究是一种分析形式,用于验证结构暴露在环境中时的损伤演变。在巴西盐碱环境中的一栋居民楼中,测量了碳酸化深度,氯离子,并应用了一种新的评估方法来确定结构退化的定量边界。结果表明,碳化深度小于混凝土表层,但结构元素中的氯离子含量大于阈值。结构恶化并立即进行结构干预以恢复可使用性水平。因此,这项工作显示了使用带有数值分析的简单检查程序来验证结构中损坏演变的可能性。