首页> 外文会议>ASME international mechanical engineering congress and exposition >Design and uncertainty analysis of a second-generation convective heat flux calibration facility
【24h】

Design and uncertainty analysis of a second-generation convective heat flux calibration facility

机译:第二代对流热通量校准设备的设计和不确定性分析

获取原文

摘要

The National Institute of Standards and Technology has developed a convective heat flux facility to allow calibration of heat flux sensors. The facility consists of a small wind tunnel that produces a two-plate. Sensors are mounted flush in the copper plate alongside a reference to measure the heat leaving the plate. Convective calibrations up to 5kW/m~2 are possible.
机译:美国国家标准技术研究所已经开发了对流热通量设备,可以对热通量传感器进行校准。该设施由一个小型风洞组成,该风洞产生两块板。传感器与参考板齐平地安装在铜板上,以测量离开板的热量。对流校准最高可达5kW / m〜2。