The seismic ruggedness of fire suppression systems is essential to safety and loss prevention in facilities housing flammable and hazardous materials, and to the successful performance of emergency response facilities, such as hospitals, following earthquakes. Fire suppression systems are not only needed to mitigate earthquake-caused fires, they must also not damage other safety systems through colapse, leakage or inadvertent actuation. For these facilities, the design of fire suppression systems should therefore be based on a thorough understanding of seismic behavior, particularly the seismic behavior of their piping joints and supports.
机译:灭火系统的抗震性对于容纳易燃和危险材料的设施中的安全和防损以及地震后应急设施(如医院)的成功运行至关重要。不仅需要灭火系统来减轻地震引起的火灾,而且还必须通过坍塌,泄漏或意外启动来破坏其他安全系统。因此,对于这些设施,灭火系统的设计应基于对地震行为,特别是其管道接头和支座的地震行为的透彻了解。