首页> 外文会议>Conference on cryogenic optical systems and instruments >Cryogenic optical performance of the Cassini composite infrared spectrometer (CIRS) flight telescope
【24h】

Cryogenic optical performance of the Cassini composite infrared spectrometer (CIRS) flight telescope

机译:卡西尼复合红外光谱仪(CIRS)飞行望远镜的低温光学性能

获取原文

摘要

Abstract: The Cassini Composite InfraRed Spectrometer half-mirror diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out-of-house and then assembled, aligned, and tested upon receipt at GSFC. A 24-inch aperture cryogenic test facility utilizing a 1024 $MUL 1024 CCD array was developed at GSFC specifically for this test. The telescope's image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the cold image performance requirement of 80% encircled energy within a 460 micron diameter cycle.!9
机译:摘要:Cassini复合红外光谱仪半镜直径铍飞行望远镜的光学性能在170 kelvin的仪器工作温度下进行了测试。望远镜组件是在戈达德太空飞行中心(GSFC)的组件,而是在GSFC收到的房屋外面,然后组装,对齐,并在GSFC收到时进行测试。利用1024 $ MUL 1024 CCD阵列的24英寸光圈低温测试设施专为此测试,在GSFC上开发了一种。测量望远镜的图像质量(测量为环绕能量),测量光谱稳定性和聚焦稳定性。金涂层铍设计超过了460微米直径循环内的80%环绕能量的冷图像性能要求。!9