Air Tightness of Buildings in Finland

机译:芬兰建筑气密性

获取原文

摘要

There are no requirements of building air tightness in Finland. Buildings always have thermal bridges and air leak routes, whose impact in decreasing comfort depends on the structures and the way of constructing. Uncontrolled air leaks are cooling the structures and causing draft and, in the long run, defects. These air leaks and thermal bridges can be found only by thermal scanning. In Finland building air tightness has been measured for over 20 years. The procedure includes two stages, in which the target is scanned by a thermal imager. The paper is based on the results of over 200 tests of one-family and detached houses. The air tightness level has improved, but there are still problems in the structural details. The monitoring procedure for therm scanning of buildings should be further developed (there is no generally accepted practice at the moment), as well as air tightness requirements should be created.
机译:芬兰建筑气密性没有要求。建筑物始终具有热桥和空气泄漏路线,其影响降低的舒适度取决于结构和构建方式。不受控制的空气泄漏正在冷却结构并导致草稿,长期缺陷。这些空气泄漏和热桥只能通过热扫描找到。在芬兰建筑气密,已经测量了20多年。该过程包括两个阶段,其中通过热成像仪扫描目标。本文基于200多个单独和独立房屋测试的结果。气密度水平改善,但结构细节仍存在问题。应进一步开发出建筑物热扫描的监测程序(目前没有公平的实践),以及应创建空气密封性要求。