We performed experiments on porcine atrial tissue fragments with a custom-built bipolar electrosurgical forceps fitted with long electrodes (20 mm) in order to create long and transmural lesions. Results show that impedance monitoring during heating and visual supervision of the lesion zone, are optimum parameters to control lesion evolution and avoid overheating in the tissue. Transmural lesions without charring were created with 15 watts of power during 10-15 seconds on initial impedances between 50-90 ohm.
机译:我们用定制的双极电外科手术镊子对猪的心房组织碎片进行了实验,该镊子配有长电极(20毫米),以产生长而透壁的病变。结果表明,加热过程中的阻抗监测和病变区域的视觉监控是控制病变发展并避免组织过热的最佳参数。在10-15秒钟内,初始阻抗在50-90欧姆之间,使用15瓦的功率产生了不烧焦的透壁病变。