首页> 外文会议>Electronic Packaging Technology Conference, 1997. Proceedings of the 1997 1st >Local thermal characteristics of a confined round jet impinging onto a heated disk
【24h】

Local thermal characteristics of a confined round jet impinging onto a heated disk

机译:受限圆射流撞击加热盘的局部热特性

获取原文

摘要

In order to achieve reliable MCM cooling with an impinging jet, a suitable jet configuration and surrounding geometry must be selected. An experimental investigation on heat transfer characteristics of an axisymmetric round jet impingement with confinement has been performed. The measurements for these experiments are performed in an axisymmetric mode, and the acquisition of all the experimental data is in steady state. A series of parametric studies are systematically conducted. The three parameters influencing heat transfer performance are jet Reynolds number (Re), ratio of jet separation distance to jet diameter (H/d), and the nozzle tube diameter (d). The ranges of these three parameters studied are Re=973-14051, Wd=1-12, and d=6.15 mm-9.20 mm. Their effects on local thermal characteristics in such a jet-impingement configuration are successively explored in the study.
机译:为了用冲击射流实现可靠的MCM冷却,必须选择合适的射流配置和周围的几何形状。进行了轴对称圆形射流撞击传热特性的实验研究。这些实验的测量以轴对称模式执行,并且所有实验数据的采集都处于稳定状态。系统地进行了一系列参数研究。影响传热性能的三个参数是射流雷诺数(Re),射流分离距离与射流直径之比(H / d)和喷嘴管直径(d)。研究的这三个参数的范围是Re = 973-14051,Wd = 1-12和d = 6.15 mm-9.20 mm。在这种研究中,已经探究了它们在这种射流冲击形态下对局部热特性的影响。