Bulk current injection (BCI) and field coupling are analytically compared in order to ascertain if current injection tests are adequate for susceptibility assessment of electronic equipment. Transmission line theory is adopted for modelling wiring harnesses, and the equivalence is discussed by comparing the effects that the two kinds of excitation techniques produce at the line ends. General results are obtained, which are not affected by any assumptions on the equipment under test. It is shown that, from the theoretical point of view, injection by means of two current probes allows equivalence with any radiated plane wave excitation. The equivalence is achieved by controlling the clamp voltage in order to match the incident field characteristics.
机译:通过分析比较大电流注入(BCI)和场耦合,以确定电流注入测试是否足以进行电子设备的敏感性评估。采用传输线理论对线束进行建模,并通过比较两种励磁技术在线路末端产生的效果来讨论等效性。获得的一般结果不受测试设备的任何假设影响。从理论上可以看出,通过两个电流探头进行注入可以等效于任何辐射平面波激发。通过控制钳位电压以匹配入射场特性来实现等效性。