Vibratory signature of electric pylons under impulse testing

机译:高压测试中电塔的振动信号

获取原文

摘要

Abstract: A nondestructive vibratory technique has been used to record the vibratory signature of electric pylons. It evidences the principal modes of vibrations. The vibration magnitude depends on the impact location and the loading amplitude. The appearance of energy dissipation mechanisms, corresponding to a damaging process, is readily detected by a change of characteristics of the recorded acceleration signals. A method based on Volterra series provides a ready mean to analyze the nonlinear response and permits us to monitor the durability of the pylon in service. The presented technique relies on the evaluation of a scalar called `nonlinear contrast,' indicating the significance of nonlinear behavior of the structure under impact loading, in comparison with a reference state. The calculation requires the identification of Volterra kernels through a multi-amplitude procedure. The fact that an unscrewed bolt has been evidenced shows that this technique is very sensitive. The second major experimental result is that the nonlinear contrast appears to be independent on the accelerometer location and direction. !19
机译:摘要:无损振动技术已被用来记录电塔的振动信号。它证明了振动的主要模式。振动幅度取决于撞击位置和载荷幅度。通过记录的加速度信号的特性变化,可以容易地检测出与破坏过程相对应的能量耗散机制的出现。基于Volterra级数的方法为分析非线性响应提供了现成的方法,并允许我们监视使用中的塔架的耐久性。提出的技术依赖于标量的评估,称为“非线性对比”,表明与参考状态相比,结构在冲击载荷下的非线性行为的重要性。该计算需要通过多振幅程序来识别Volterra内核。已经证明拧开螺栓的事实表明该技术非常敏感。第二个主要实验结果是非线性对比度似乎与加速度计的位置和方向无关。 !19